Self-adhesive,polymer-modified bituminous waterproofing membrane
The product is a self-adhesive SBS polymer modified bituminous waterproofing sheet membrane, with a cross laminated HDPE film on one side and a silicone release film on the other.
USES
It is recommended for waterproofing or damp-proofing for concrete protection. It may be used for horizontal and vertical application for tanking be low ground structures, subways and retaining walls
CHARACTERISTICS/ ADVANTAGES
- Cold applied, self-adhesive and easy to
- Excellent adhesion to vertical and horizontal sur
- Excellent resistance to chlorides, sulphates,dilute alkalis and acids.
- Good tear and puncture resistance
PRODUCT INFORMATION
Product declaration: Bonded sheet membrane according to IS 16471: 2017
Construction:
Compound- SBS modified bitumen
Top layer – Cross laminated HDPE film
Bottom Layer – Release liner PE film
Packaging
Roll width – 1.0 m ± 0.01 m
Roll length – 20.0 m ± 0.2 m
Shelf life: 12 months from date of production
Storage conditions:
The product must be stored in original unopened and undamaged packaging in dry conditions and temperatures between +5 °C and +30 °C. Store in a horizontal poistion in pallets with maximum height 1 meter. Do not stack pallets of the rolls on top of each other, or under pallets of any other materials during transport or storage. Protect from long exposure to direct sunlight.
Mass per unit area:
Membrane Thickness (Composite)
1.5-mm
2.0 mm
Areal Weight
1.6 kg/m2
2.1 kg/m2
TECHNICAL INFORMATION
Resistance to static puncture
Important Note :All Technical Valu-es/lnformation given in the Product Data Sheet are for 1.5 mm composite thickness membrane
Tensile strength
Tensile strength of membrane – 4 N/mm2
(ASTM D 412)
Tensile strength of HOPE film (L/T) – 2′: 48/42 N/mm2
(ASTM D 882)
Elongation: > 300% (ASTM D412)
Resistance to tear (nail shank):
Tear Resistance of Membrane (L/T) – 2′: 25/33 N/mm
(ASTM D 624)
Tear Resistance of HOPE film (L/T) – 2′: 160/155 N/mm
(ASTM D 624)
Flexibility at low temperature: No cracks at -15 °C (ASTM D1970)
Softening point: > 102 °C (ASTM D36)
Water tightness: No Leakage @ Hydrostatic Pressure of 7 Bar (BS EN 5385 – 2000)
Water vapour transmission: < 0.3 g/m2 /24 hours (ASTM E96)
Chemical resistance: Resistant to 10% NaCl, Ca(OH}z,H2S03) (EN 1847:2009)
APPLICATION INFORMATION
Ambient air temperature: +5 °C min./ +45 °C max
Substrate temperature: +5 °C min. / +45 °C max
BASIS OF PRODUCT DATA
All technical data stated in this Product Data Sheet are based on laboratory tests. Actual measured data may vary due to circumstances beyond our control.
IMPORTANT CONSIDERATIONS
Important Note :The Technical Values/Information giv en in the Product Data Sheet are for 1.5mm composite thickness membrane
ECOLOGY, HEALTH AND SAFETY
User must read the most recent corresponding Safety Data Sheets (SOS) before using any products. The SOS provides information and advice on the safe handling, storage and disposal of chemical products and con tains physical, ecological, toxicological and other safety-related data.
FURTHER DOCUMENTS
One roll of SikaShield®-722 after deducting for the overlaps, covers an area of 18.7m x 0.98m. i.e. approximately 18.33 m2 per 20mxlm roll.
However,slightly reduced area coverage may occur while treating oddly shaped areas or where many joints are required
- Pressure roller
- Clean lint-free cloth
- Metal straight edge for cutting
- Hot air gun (Leister Triac)
- Automatic thermal jointing machine (Leister Twinny or Leister Varimat,etc)
APPLICATION METHOD/ TOOLS
Surface Preparation
It is essential to create a sound and solid substrate to eliminate movement during the concrete pour. Sub strates must be regular and smooth with no gaps or voids. Grout around all penetrations for stability
Horizontal Blinding
The blinding must be free of loose aggregate, voids, surface irregularities and sharp protrusions. The sur face needs to be in a touch dry condition. SSD condi tion (no standing water) is also acceptable.
Vertical Surfaces
The vertical surfaces should have proper levelled bri: work, blockwork or formwork with ut any irregularities. For the case of sheet piles, the substrate should be made regular with a smooth finished shotcrete or sacrificial formwork to be installed
Installation
Please refer to the Sika” Method Statement: SikaProof®-7311.2 mm for detailed installation guidelines or contact Sika” Technical Services team for support
Membrane Repair
Generally, the membrane is very tough, and the execution should not encounter any repair. In the most extreme cases, if for some site issues, there is any reason to do a patch work, then please contact our Sika” Technical Services team for the rectification procedure
Pouring of Concrete
It is recommended that concrete is poured within a maximum of 45 days after the HOPE membrane has been installed on the sub-base (e.g. PCC). Care should be taken to avoid any damage to the membrane dur ing laying steel reinforcement, consolidation and com paction of concrete.
Care should be taken to avoid any damage to the membrane during the reinforcement laying. Addition ally, during placement of concrete, the vibrator needle should not touch the placed HOPE membrane. For best results use Sika” Smart Dynamic Concrete
LOCAL RESTRICTIONS
Note that as a result of specific local regulations the declared data and recommended uses for this product may vary from country to country. Consult the local Product Data Sheet for exact product data and uses.